Transmission Modeling and Analytics
Models, tools and methods to ensure resilient, reliable and clean transmission networks.
Research and Development Challenges
EPRI’s Transmission Planning research area supports the development and validation of planning study models, planning processes and frameworks, and reliability and resiliency assessment analytics. These are required to build a reliable, resilient, and economic transmission grid that integrates an evolving generation mix to supply an increasingly complex load, that can also act as a system resource. A major focus is on accurately representing emerging loads—such as EV charging stations, data centers, and hydrogen electrolyzers—alongside enhancements to the composite load model and support for utility adoption. Measurement-based approaches are being developed to improve load modeling accuracy, while aggregated DER models are being refined to support FERC Order 2222, ensuring better representation of distributed resources in transmission planning. Significant advancements are also being made in modeling and control of HVDC systems, including offshore wind integration and grid-forming capabilities. Generic models for FACTS and HVDC are being updated to reflect evolving system dynamics. Stability analysis is being strengthened through improved screening methods and new guidelines for sub-synchronous oscillation (SSO) analysis in EMT environments. Tools like the Advanced Reliability Toolset (ARTS) are being enhanced to support high-IBR systems, with improvements in contingency screening and node-breaker modeling using EMS data. On the planning front, frameworks such as the Resilient System Investment Framework (RSIF) and High Level Screening (HiLS) tool are being upgraded to support decarbonization pathways. Automated powerflow case creation and coordinated expansion planning tools (JHSMINE and ACEP) are being refined for co-optimization. Data analytics and outage statistics are being leveraged to improve reliability assessments, while topical webcasts and insights are being offered to keep stakeholders informed. Power quality and harmonic compliance remain critical, with updates to tools like GICHarm and B2E, and new guides addressing flicker, TRV, lightning transients, and temporary overvoltage. IBR harmonic models and study guides are also being revised. Finally, planning frameworks like CPLANET are being enhanced to integrate Grid Enhancing Technologies (GETs), with updated reference guides supporting their deployment. Collectively, these efforts aim to ensure grid reliability, resilience, and adaptability in the face of rapid technological and structural change.
.
Related Deliverables
Validation of Reduced System Models
3002029744
Summarizes impedance scanning techniques to validate reduced models.
Planning for HA of Utility-Scale IBRs
3002029749
Presents further development of EMTP custom devices for modeling inverter-based generation resources and their applications to perform harmonic studies.
Guidelines for Equipment for Harmonics
3002029751
Presents a methodology for developing harmonic models for common transmission equipment.
Performing Circuit Breaker TRV Studies
3002029753
A guide for engineers to create and conduct TRV studies and assess the results against applicable industry standards.
GDV Assessment and Planning Guide
3002029754
Application guide for conducting geomagnetic disturbance (GMD) vulnerability assessments per TPL-007.
Inverter Interaction Screening
30020297824
This document strategizes how to pre-emptively screen for inverter interactions and plan for mitigation as required.
Impedance Characterization of PE Loads
3002029829
Assessing stability impact of large PE loads on power system using impedance characteristics.
GDO Reference Guide
3002029831
A reference for creating geomagnetic disturbance (GMD) operating guidelines.
Application Guide for STATCOMs
3002030464
Guide offers application guidance on using STATCOMs to mitigate fluctuating load impacts, enhance BPS flexibility, and improve system performance safely and effectively
Impact of Inverter-Based Resources
3002030712
Documents flicker levels for a changing resource mix and proposes potential mitigation strategies.
Harmonic Emission Limit Coordination
3002030713
Demonstrates the need for a close coordination in the management of harmonics on the BPS.
ZSCAN v1.4
3002029743
ZSCAN-EMT is an impedance scan module that uses PSS®E to perform an impedance scan and extract the impedance from a particular bus of interest.
PRE-SW: ZSCAN-EMT v1.2 Beta
3002029745
ZSCAN-EMT is an impedance scan module that uses PSCAD to perform an impedance scan and extract the impedance from a particular bus of interest
EPRI TRV (ETRV) Screening Tool
3002029746
Screening tool to conduct TRV studies and assess the results against applicable industry standards.
GICharm
3002029748
GIC harmonic tool to conduct the analysis needed to consider removal of equipment that may be susceptible to harmonics.
ZSCAN-online
3002029826
Online version of the impedance scanning tool to periodically scan system to monitor changes and associated stability implications due to contingencies etc.
Signal Damping Analysis Tool V3.05
3002030562
Tool to perform oscillation analysis signals observed in simulations or in the field
Energize (E-Energize) Screening Tool
3002030860
Screening tool to conduct transfomer and motor inrush studies to examine system impacts.
E-Switching
3002030957
Tool to perform insulation coordination studies with an easy- to-use GUI which minimizes user interventions.
ARTS Tool V2024
3002031027
ARTS tool generates NERC TPL contingencies definitions and post-processing contingencies to identify critical ones.
Transmission Solution Software (CPLANET)
3002029839
Ooptimized transmission solutions that combined advanced transmission technologies, energy storage and conventional projects.
Advanced Methods for TRA
3002029834
Ooptimized transmission solutions that combined advanced transmission technologies, energy storage and conventional projects.
Line Rating in Transmission Planning
3002029841
Analyze the implications of using advanced line rating technologies, such as AAR and DLR, for long-term transmission expansion planning
Grid-Enhancing Technologies RG 2023 Ed.
3002029843
Provide new insights on the economic, reliability, and environmental benefits of advanced transmission grid technologies.
HVDC Planning Guide - 2024 Update
3002029844
Summary of HVDC planning processes, study types, and modeling and simulation tool guidelines.
System Impact of HVDC Connections
3002029847
Provides insight into system reliability implication of HVDC links, identifies mitigation options, including advanced use of converter control capabilities.
GFM-ID Procedures P
3002030168
The document develops procedures and methods to help identify and verify IBR performance in simulation models.
IBR Short-Circuit Network Equivalencing
3002030169
Documents results of network equivalencing methods for fault and protection studies in systems dominated by IBRs.
IBR SC Modeling
3002030170
Summarizes the latest research and developments in short-circuit modeling of inverter-based resources.
Modeling of IBR and Load Interactions
3002030173
Summarizes the latest research on inverter-based resources and load interactions.
POD with IBRs
3002030172
Investigates the capability of inverter-based resources to provide power oscillation damping.
Boundary between EMT-RMS Domain TI
3002030470
The aim is to identify the characteristics that can help define the boundary between EMT and RMS domains.
IBRs and Grid Interactions
3002031234
Document updates ongoing work on understanding IBR-grid interactions, including shunt and series compensation, and evaluates an approach to developing reduced models.
Modular Eigenvalue Analysis
3002031345
Provides an overview of a modular technique to evaluate small signal stability of the power system.
Grid-Forming Inverter Technologies P
3002031346
Discusses the various nuances associated with deployment of grid forming technology on a mass scale and identifies challenges and opportunities.
EPRI Technology Transfer to NERC SPIDER
3002031525
Document NERC stakeholder discussions and publications on the system planning impacts of distributed energy resources for 2022-2024.
Grid Strength Assessment Tool
3002030167
Helps in evaluating various system strength metrics during planning.
Generic GFM Model - PSS(R)E v1.0 P
3002030987
A positive sequence model is used in PSS®E planning studies to evaluate the need, value, and location of grid-forming devices.
Generic GFM Model - PSLF v1.0 P
3002030988
This positive sequence model can be used in PSLF planning studies to evaluate the need, value, and location of grid-forming devices.
Generic GFM Model - PowerFactory v1.0 P
3002030989
This positive sequence model can be used in PowerFactory planning studies to evaluate need, value, and location and grid forming devices.
Key projects and Related Efforts